Currency
Language
Spareparts Markt

Vaillant Air Pressure Switch Huba 80/68 - 0020041905

Stock Code: KG0037599
Vaillant Air Pressure Switch Huba 80/68 - 0020041905
Vaillant Air Pressure Switch Huba 80/68 - 0020041905
UPC: 0020041905
Pressure switch 80/68 PA (monostat) for a turbocharged gas boiler Manufacturer: Vaillant Purpose of the compo... Read More
$14.95
2 or more $13.46 5 or more $11.96

Check Compatibility

You can check whether this product is suitable for you by typing the model of your machine in the box below.

    Description
    Vaillant Air Pressure Switch Huba 80/68 - 0020041905

    Product Classification: Compatible

    Pressure switch 80/68 PA (monostat) for a turbocharged gas boiler
    Manufacturer: Vaillant
    Purpose of the component: For gas boilers
    Component type: Pressure switch
    Condition: New
    Additional characteristics:
    Fuel type: Gaseous
    The pressure switch of the Vaillant gas boiler controls the smoke removal process (removal of combustion products) and the operation of the fan, gives a signal on the operation of the boiler burner, the spare part is often called a monostat, pneumatic relay or differential smoke pressure switch. A membrane is installed inside the pneumatic relay, to which a microswitch is attached. The silicone tube serves to drain the condensate. In the pressure switch housing, the membrane is affected by atmospheric air pressure and the pressure of flue gases emitted by the fan. As a result, two pressure impulses (negative and positive) are combined. During normal operation of the burner, the fan operates and pressurizes the diaphragm, which, when moved, changes the state of the microswitch from normally open to normally closed. During ignition, the microprocessor energizes the fan relay contacts and the fan turns on. After starting the fan, the diaphragm of the manostat changes its position and switches the contacts of the mikrik along the way. Contacts c and no close. The microprocessor connects the ignition and flame control section. After the end of the boiler operation, the relay contacts must return to their original position (contacts c and nc are closed).
     
    Suitable Models:
     
     
    Vaillant : VM 242/4-5, VM 242/4-5 R2, VM 282/4-5, VM 282/4-5 R2, VMW 21/245/4-3 R3, VMW 21/245/4-5, VMW 21/245/4-5 R3, VMW 24/282/4-5 RV, VMW 24/282/4-5 RV R2, VMW 255/4-7, VMW 255/4-7 R3, VMW 28/322/4-5 RV, VMW 28/322/4-5 RV R2, VMW 282/4-3 R1, VMW 282/4-3 R2, VMW 32/362/3-5 RV, VMW 32/362/3-5 RV R2
     
    Reviews (0)

    Ask Question
    Do you have question? You can send your question to us with using below form.


    Continue